Cisco PGW 2. 20. 0 Softswitch Release 9. Software Installation and Configuration Guide - Chapter 2. Installing the Sun Solaris 1. Operating System . Here is a convenient procedure to know for Solaris 8 and below. Install a Solaris Boot Block; Change Access and Modification Times on a File. Copy a Solaris Boot Drive to a New Disk. With this document I did on SUNfire 440 with Solaris 10. Installing Solaris 8 bootblock without Solaris Install CD Solaris. Installing Solaris 8 bootblock without Solaris Install CD. The following sections contain these instructions. Note In the following procedures, your responses to prompts sometimes depend on the disk drive size or other particulars of your system. These are pointed out as you follow the procedures. Two platform types are used: Sparc- based and Opteron- based. The platforms that are supported for these products are identified in the. Cisco PGW 2. 20. 0 Softswitch Hardware Installation Guide (Release 7 & 9). You can skip the installation of the software. You must install all of the Cisco PGW 2. Softswitch software patches. If the two files exist, the software was already installed. If the system returns the message below, the software was already installed. Note Be sure to have the required information listed in Chapter 1 . Note Allow at least 2 hours downtime for the installation of the Cisco PGW 2. Softswitch software environment. The Solaris boot block. Restore the boot block as follows. To learn more about the Solaris boot process, read the boot. How to install boot block in Solaris 10. If your OS is Update5 before, it may be failed for boot to copy bootblk of Install Media(Update6 later). 4) SPARC: Installing Solaris. Human Rights Advocacy Centre. Note The text in the screens displayed throughout this document might differ slightly from the text displayed on your console. The screen displays are for reference only and should be treated as examples. Note Most of the steps in the installation process ask you to press F2 to continue. However, F2 does not apply to all console types. If it does not apply on your system, you should press Esc- 2 instead. Tip During the installation process, monitor system output frequently for error messages and correct any error conditions before continuing with the installation. This table is referenced throughout this chapter. Other Solaris installations are similar, with slight variations. These instructions will note the differences between the sets of installation instructions. Step 1 Choose one of the following options to connect the Cisco PGW 2. Softswitch: . Step 2 This step is optional—if you decide to skip this step, go to Step 3. Place the system in single- user mode by shutting down the standby machine. When the machine prompts for a password, type either ^ - d to proceed with normal startup, or the root password for system maintenance. Step 3 Load the appropriate version of the CD- ROM labeled Cisco Solaris 1. Operating System Jumpstart Disk for Sparc- based Platforms into the CD- ROM drive. Step 4 If the system is currently running, log in as root. Step 5 Bring the system to the ok prompt by entering the following command: # init 0. Note If you are prompted to select a language before booting from the CD, go to the ok prompt by sending a break on the console port. On Sun Sparc- based platforms, the key sequence < cr> #. From the system controller prompt, use the break - y command to break out of the operating system and console - f command to return to the console display. You should see the ok prompt. Step 6 Boot the system from the CD- ROM drive by entering the appropriate command: ok boot cdrom - install. Information similar to the following is displayed: ok boot cdrom - install. SC Alert: Host System has Reset. Probing system devices. Probing I/O buses. Sun Fire V2. 10, No Keyboard. Copyright 2. 00. 5 Sun Microsystems, Inc. In a. few cases, mounts that cross different domains might cause files to. Other Solaris installations are similar, with slight variations. These instructions will note the differences between the sets of installation instructions. Step 1 Choose one of the following options to connect the Cisco PGW 2. Softswitch: . Note Cisco recommends that you connect to the Cisco PGW 2. Softswitch using a keyboard and monitor. If you choose to connect through the console port, you need to ensure that Console Redirection is enabled as instructed in Step 6. Step 2 Follow these steps to connect to the target system through a serial port: a. Log in to the SP (Service Processor) as an Administrator: login: root. Type the following command to start the ILOM Service Processor (SP) GUI: start /SP/console. Step 3 This step is optional—if you decide to skip this, go to Step 4. Place the system in single- user mode by shutting down the standby machine. When the machine prompts for a password, type either ^ - d to proceed with normal startup, or the root password for system maintenance. Step 4 Load the appropriate version of the CD- ROM labeled Cisco Solaris 1. Operating Software Startup Disk for Opteron- based Platforms into the CD- ROM drive. Note If your servers do not have a CD- ROM drive, see the . Step 5 If the system is currently running, log in as root. Step 6 Boot the system from the CD- ROM drive by entering the appropriate command: # reboot. Note You may be prompted during the reboot to enter Ctrl- B or Ctrl- C to open configuration tools for your hardware. You do not need to open any of these tools to complete this installation. Press the F2 key to open the Setup menu. The Setup menu opens after the self- tests have been completed. Go to the BOOT setup information. Ensure that the CD- ROM is the first bootable device in the list. Choose the Advanced menu from the category selections at the top of the screen. If you connected to the Cisco PGW 2. Softswitch using the console port, ensure Console Redirection is set to enable or always. Save your changes and exit the Setup menu. Customizing system files. Mount points table (/etc/vfstab). Unselected disk mount points (/var/sadm/system/data/vfstab. Network host addresses (/etc/hosts). Network host addresses (/etc/hosts). Environment variables (/etc/default/init). Cleaning devices. Customizing system devices. Physical devices (/devices). Logical devices (/dev). Installing boot information. Installing boot blocks (c. Updating system firmware for automatic rebooting. Installation log location. In a. few cases, mounts that cross different domains might cause files to. The Cisco PGW 2. 20. Softswitch uses neither of the two applications. Ignore them while you log in on the platform. Power on the Sun server (for example, X4. Opteron server), and press F2 to enter BIOS settings page. Click Advanced tab in the BIOS setup utility. You see a screen similar to the one in Figure 2- 1. Highlight IPMI 2. Configuration in the list. Highlight LAN Configuration in the list. Choose Static in the IP Assignment. Enter IP address, subnet mask, and default gateway as the following example: IP address = 1. Subnet Mask = 2. 55. Default Gateway = 1. Note The IP address, subnet mask, and default gateway values in the above example is for your reference. You should enter these values according to your actual network configuration. Select Commit and save the changes, then press F1. BIOS. Connect the Sun Server with a console cable on the SERIAL MGMT port. At the ILOM prompt - > , enter the following commands to configure the IPMI IP settings: - > set /SP/network pendingipaddress=1. SP/network pendingipnetmask=2. SP/network pendingipgateway=1. SP/network pendingipdiscovery=static. SP/network commitpending=true. Note The IP address, subnet mask, and default gateway values in the above example is for your reference. You should enter these values according to your actual network configuration. Step 2 Install Java—As a prerequisite for running Oracle ILOM, please make sure that you have Java installed on your computer (Java 6 or later). Step 3 Start SP ILOM with the following procedure: a. Open a browser (preferably Mozilla Firefox v. Java support is enabled in the browser settings. Remove or disable Proxy- settings. Enter the SP IP address in the address bar of the browser (for example, https: // 1. Login as root and use the password changeme. Click the Remote Control tab. You will see a screen similar to the one shown in Figure 2- 4: Figure 2- 4 ILOM- Remote Control Tab f. If a pop up window appears for warnings and security, tick the trust point and click RUN. Click Download Client. Save the Storage. Re. Dir. jar file in local C: drive. If the file is in . Step 4 ILOM Storage Redirection a. Insert the JS1. 1 Jumpstart CD . Open DOS command prompt on the local computer. Enter the following command, where D: \ is your local CD- ROM drive label, and IP address is the SP IPMI address of the Sun server: C: \> java - jar Storage. Redir. jar. storageredir>. D: \ - u root - s changeme - p 2. If you get the error . Re- execute the start command, and you should receive an error like . If you do not get the error, the CD- ROM is probably not mounted or redirected. Keep this DOS window running in background. Step 5 Enable virtual CD- ROM option in BIOS: Note This step is mandatory in some servers such as Sun Netra X4. M2 and Sun Fire X4. CD- ROM (redirected via ILOM) detectable in the Boot options. Go to the Boot tab in BIOS Setup Utility, and you will see a screen similar to Figure 2- 6: Figure 2- 6 BIOS Setup Utility- Boot Tab b. Save the BIOS configuration and exit. Step 6 ILOM Console a. In the Remote Control tab of SP ILOM, click Launch Remote Console and it opens in Java. In the Devices tab, select keyboard and mouse. Hard- reboot the Sun server. Wait until the Sun server boots and follow the screen on the Remote Console. Then you will see the message similar to the following: Initializing Intel(R) Boot Agent GE v. PXE 2. 1 Build 0. Wf. M 2. 0). Initializing and establishing link.. When you see a menu of available Boot- Source options, choose the second option . Then you will see the message similar to the following: Initializing........./. Connect the Sun server with a console cable on Serial Mgmt port. After you connect to the Sun server with a console cable, you will get a - > prompt. Enter the following command: - > start /SP/console. You will see the Solaris installation steps and decompressing of files on the server (size 6. MB). After completion you will receive the message similar to the following: + awk . Note down the AMI Virtual CDROM device name (as shown on screen after Solaris installation, in the above example, which is /dev/dsk/c. It is useful later for mounting the CD- ROM for installing core. After auto- reboot, you will get a # prompt. Enter the following command: # sys- unconfig. SPARC: How to Install a Boot Block on a System Disk. Install a boot block on the system disk.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. Archives
December 2016
Categories |